Re: Generator

It is truly an odd duck of a panel, there are only four full-sized spaces underneath the main breaker. I've never personally been a fan of meter main combinations, because one part always fails first and you have to replace the whole unit. They're very common in Davie and Plantation and houses built...
by mohshard
Thu Aug 06, 2020 5:55 am
Forum: General Discussions
Topic: Generator
Replies: 61
Views: 17306

Re: Generator

It is a GE meter/main combo. If he had shown another 18 in up you would see the meter. You can see an FPL tamper tag if you look closely. The main breaker actually takes up both sides of the bus under the metal deadfront. So a side by side interlock wouldn't work I installed an interlock in one of t...
by mohshard
Sun Aug 02, 2020 7:03 pm
Forum: General Discussions
Topic: Generator
Replies: 61
Views: 17306

Re: Generator

Open the lid on the outdoor box. Take a picture of it from 4 feet back. Measure the distance between the main breaker and the breakers under it.
by mohshard
Fri Jul 31, 2020 8:05 pm
Forum: General Discussions
Topic: Generator
Replies: 61
Views: 17306

Re: Generator

Outside.
by mohshard
Fri Jul 31, 2020 12:33 pm
Forum: General Discussions
Topic: Generator
Replies: 61
Views: 17306

Re: Generator

In the last for years, I pulled out probably five or six of those transfer switches and installed interlock kits for the flexibility and ease-of-use. Could you please post a link or more info on the interlock kits, I would like learn more and maybe get one for my house. I use my 220v 30a plasma cut...
by mohshard
Fri Jul 31, 2020 11:57 am
Forum: General Discussions
Topic: Generator
Replies: 61
Views: 17306

Re: Generator

Edited to add. With the generator you've got that transfer switch is sufficient. However if you ever get a bigger heavy duty generator it won't be. With an interlock kit, you can run anything in the whole house easily. With one of those, you can only run what's on the transfer switch. If you want to...
by mohshard
Fri Jul 31, 2020 10:02 am
Forum: General Discussions
Topic: Generator
Replies: 61
Views: 17306

Re: Generator

Those transfer switches are typically designed for a 30 amp interface. So you'll be able to run your fridge a few lights and ceiling fans. If you ever buy a bigger generator, you have to upgrade the transfer switch. If you get an interlock device, you're turning the whole house off from FPL power, a...
by mohshard
Thu Jul 30, 2020 10:32 pm
Forum: General Discussions
Topic: Generator
Replies: 61
Views: 17306

Re: Generator

What outside panel do you have? Inside panel. Where is the generator inlet going to be installed?


Those transfer switches suck. Look into interlock devices for whole house power.